Tuesday, 17 March 2015
Cache Error on SRX5K SPC II causes flowd process core
Product Affected:
This issue is fixed in Junos OS 12.1X44-D40, 12.1X46-D25, 12.1X47-D15 and higher versions.
NOTE: There is no known way to monitor the system status before the flowd core due to cache error and there is no known workaround available. If the system reports a flowd core, please open a "Technical Service Request" on the Case Manager.
SRX5400/5600/5800 using SPC II (SRX5K-SPC-4-15-320) and running with Junos OS :
Alert Description:- 12.1X44-D10/D15/D20/D25/D30/D35
- 12.1X45-D10/D15/D20/D25/D30
- 12.1X46-D10/D15/D20
- 12.1X47-D10
A cache error exception
could happen randomly in rare conditions on SRX5K SPC II (Services
Processing Card, SRX5K-SPC-4-15-320) when the SPC is referring to an
invalid physical address in memory, which triggers flowd process core
and all SPCs restart on the local node. If the chassis cluster feature
is enabled, the data plane will fail over to the other node.
For example, the following output will be shown when this issue happens.
This issue can be tracked via PR1005195.
Solution:For example, the following output will be shown when this issue happens.
root@SRX5K> show system core-dumps -rw-rw---- 1 nobody wheel 941023387 May 12 23:45 /var/tmp/flowd_xlr-SPC7_PIC3.core.0.gz
root@SRX5K> show log messages ... May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: cpuid = 26 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3-ADDRESS_ERR: pid 251 (flowd_xlr), uid 0: pc 0xffffffff802927e0 got a read fault at 0xffffffff802927e0 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: Trapframe Register Dump: May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: zero: 0000000000000000 at: fffffffffffffdff v0: 0000000000000001 v1: 00000001c9322248 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: a0: ffffffff80a00406 a1: 00000000200f09fc a2: 0000000000000000 a3: 00000000243ab1b8 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: t0: 0000000000009e63 t1: 00000001eb0e4a50 t2: 00000002dab903c0 t3: 00000002dab90390 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: ta0: ffffffffd1ebbad8 ta1: 0000000000000000 ta2: 0000000000000000 ta3: 0000000000000000 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: t8: 000000000000003a t9: 0000000020105650 s0: 000000000000001a s1: 00000000243ab288 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: s2: 00000000243ab1b8 s3: 00000000243ab1b8 s4: 000000000000001a s5: 00000000241d0000 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: s6: 0000000021950000 s7: 00000001c9321e88 k0: 0000000000000000 k1: 0000000000000000 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: gp: 0000000000000000 sp: 0000000fdd5eaea0 s8: 000000000000001a ra: 00000000200f0bc8 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: sr: 00000000508198f3 mullo: 0000000000000000 mulhi: 0000000000000000 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: pc: ffffffff802927e0 cause: 0000000000000010 badvaddr: ffffffff802927e0 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: pc address 0xffffffff802927e0 is inaccessible, pte = 0x0 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-2: flowd core, May 12 23:43:31 fpc7 Cowra: %PFE-3: XLP3 flowd_xlr core dump, current state SPU_STATE_WORKING. May 12 23:43:31 fpc7 flowd_xlr coredump start, ecc regs: %PFE-3: 0,0,0,0 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-2: stop xaui rx and drain packets on lbt cpu 4 May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-2: msgring_drain_process: bind thread to hwtid (4) cpuid(4) May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-2: [msgring May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-2: _drain_process]476 msges drained May 12 23:43:31 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-2: Kernel thread "msgdrainthr4" (pid 41228) exited prematurely. May 12 23:43:32 fpc7 Cowra: %PFE-3: XLP3 flowd_xlr down, current state SPU_STATE_CRASH. info: Flowd down, flowd_xlr_statusfound flowd in coredump. May 12 23:43:32 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: spu_cobar_send_mail_unlocked: New mail (6) tried 2 times to be sent, finally sent May 12 23:45:05 /kernel: %KERN-4: peer_inputs:4300 VKS0 closing connection peer type 10 indx 31 err 0 May 12 23:45:05 /kernel: %KERN-3: pfe_send_failed(index 31, type 10), err=32 May 12 23:45:05 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-4: peer_inputs:4300 VKS0 closing connection peer type 10 indx 31 err 0 May 12 23:45:05 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 kernel: %USER-3: pfe_send_failed(index 31, type 10), err=32 May 12 23:45:10 /kernel: %KERN-3: ###rdp_usr_detach tcb NULL socket 0xc6a824d4 May 12 23:45:15 fpc7 Cowra: %PFE-3: XLP3 flowd_xlr down complete. May 12 23:45:15 (FPC Slot 7, PIC Slot 3) SPC7_PIC3 init: %AUTH-6: flowd_xlr (PID 173) exited with status=0 Normal Exit May 12 23:45:16 chassisd[1506]: %DAEMON-5-CHASSISD_IFDEV_DETACH_PIC: ifdev_detach_pic(7/3) May 12 23:45:16 chassisd[1506]: %DAEMON-5-CHASSISD_SNMP_TRAP7: SNMP trap generated: Fru Failed (jnxFruContentsIndex 7, jnxFruL1Index 8, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName FPC: SRX5k SPC II @ 7/*/*, jnxFruType 3, jnxFruSlot 7) May 12 23:45:16 alarmd[975]: %DAEMON-4: Alarm set: PIC color=RED, class=CHASSIS, reason=FPC 7 PIC 3 SPU flowd core dump complete May 12 23:45:16 chassisd[1506]: %DAEMON-5-CHASSISD_PIC_OFFLINE_NOTICE: Taking PIC 3 in FPC 7 offline: SPU flowd core dump complete May 12 23:45:16 craftd[976]: %DAEMON-4: Major alarm set, FPC 7 PIC 3 SPU flowd core dump complete May 12 23:45:16 chassisd[1506]: %DAEMON-5-CHASSISD_FRU_OFFLINE_NOTICE: Taking FPC 7 offline: Reset on SPC/SPU failure May 12 23:45:16 chassisd[1506]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(7) May 12 23:45:16 chassisd[1506]: %DAEMON-5-CHASSISD_FRU_OFFLINE_NOTICE: Taking FPC 0 offline: Reset on SPC/SPU failure May 12 23:45:16 chassisd[1506]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(0) ....
- SPU kernel detected user space address error - %USER-3-ADDRESS_ERR: pid 251 (flowd_xlr), uid 0: pc 0xffffffff802927e0 got a read fault at 0xffffffff802927e0
- SPU kernel started to generate flowd core - %USER-2: flowd core`) after collecting registry values
- Chassisd detached affected SPC - %DAEMON-5-CHASSISD_IFDEV_DETACH_PIC: ifdev_detach_pic(7/3)
- Chassisd offlined affected SPC due to SPU flowd core dump - %DAEMON-5-CHASSISD_PIC_OFFLINE_NOTICE: Taking PIC 3 in FPC 7 offline: SPU flowd core dump complete
- Chassisd reset all SPCs - %DAEMON-5-CHASSISD_FRU_OFFLINE_NOTICE: Taking FPC 0 offline: Reset on SPC/SPU failure
This issue can be tracked via PR1005195.
This issue is fixed in Junos OS 12.1X44-D40, 12.1X46-D25, 12.1X47-D15 and higher versions.
NOTE: There is no known way to monitor the system status before the flowd core due to cache error and there is no known workaround available. If the system reports a flowd core, please open a "Technical Service Request" on the Case Manager.
Tuesday, 10 March 2015
Junos OS 12.1X46-D30 is not recommended with IDP feature due to significant detection rate drop
Product Affected:
Alert Description:
This issue is fixed in Junos OS 12.1X46-D31 (Service Release), 12.1X46-D35 (scheduled to be released in end of April, 2015), and later releases.
12.1X46-D31 Download Links
SRX5400/5600/5800
SRX1400/3400/3600
SRX100/110
SRX100, SRX110, SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, and SRX5800 running with Junos OS 12.1X46-D30
Alert Description:
Due to software DFA
(Deterministic Finite Automata), which is used for IDP signature pattern
match, code change on Junos OS 12.1X46-D30, IDP detection rate will be
dropped significantly when the following conditions are met :
What SRX platforms use the software DFA?
Solution:- Upgraded to Junos OS 12.1X46-D30
- IDP feature is configured on a security policy with IDP active-policy
- Software DFA is used
What SRX platforms use the software DFA?
- SRX100, SRX110, SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, and SRX5800 use software DFA
- SRX210, SRX220, SRX240 SRX550, and SRX650 use hardware DFA
This issue is fixed in Junos OS 12.1X46-D31 (Service Release), 12.1X46-D35 (scheduled to be released in end of April, 2015), and later releases.
12.1X46-D31 Download Links
SRX5400/5600/5800
- https://download.juniper.net/cust-svc/srx/junos-srx5000-12.1X46-D31-domestic.tgz
- https://download.juniper.net/cust-svc/srx/junos-srx5000-12.1X46-D31-domestic.tgz.md5
- https://download.juniper.net/cust-svc/srx/junos-srx5000-12.1X46-D31-domestic.tgz.sha1
SRX1400/3400/3600
- https://download.juniper.net/cust-svc/srx/junos-srx1k3k-12.1X46-D31-domestic.tgz
- https://download.juniper.net/cust-svc/srx/junos-srx1k3k-12.1X46-D31-domestic.tgz.md5
- https://download.juniper.net/cust-svc/srx/junos-srx1k3k-12.1X46-D31-domestic.tgz.sha1
SRX100/110
Tuesday, 3 March 2015
SRX: JTAC Recommended Junos Software Versions
JTAC recommended versions of Junos software are listed to assist with determining which version of software to download and install.
SRX Series Services Gateways
| Platform | JTAC Recommended Junos Software by Platform | Release Type | Last updated |
|---|---|---|---|
| SRX100B/H | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX100H2 (*1) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX110H | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX110H2 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX210B/H/BE/HE | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX210H2 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX220H | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX220H2 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX240B/H/B2/H2 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX550 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX650 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX1400 (*2) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX1400 w/NP-IOC (See Note 2) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX3400 (*2) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX3400 w/NP-IOC (See Note 2) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX3600 (*2) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX3600 w/NP-IOC (See Note 2) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX5400 (See Note 6) | Junos 12.1X46-D30.2 | Standard | 25 Feb 2015 |
| SRX5600 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX5600 w/SPC II (See Notes 3, 4, 5) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX5600 w/IOC II (See Note 6) | Junos 12.1X46-D30.2 | Standard | 25 Feb 2015 |
| SRX5800 | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX5800 w/SPC II (See Notes 3, 4, 5) | Junos 12.1X44-D45.2 | Standard | 19 Feb 2015 |
| SRX5800 w/IOC II (See Note 6) | Junos 12.1X46-D30.2 | Standard | 25 Feb 2015 |
Friday, 13 February 2015
Junos OS 14.1R4
Product Affected:
Consult Release Notes:
For new and changed features, changes in behavior, known behavior and issues, resolved issues, and more, refer to:
Download Junos OS Software:
1. Go to Junos Platforms - Download Software page.
2. Select your product.
3. Under 'Version' on the right, select your version.
4. Click the "Software" tab.
5. Select the Install Package Release needed, and follow the prompts.
M-series, MX-series, T-series, PTX-series, EX-Series
Alert Description:
Junos OS 14.1R4 is now available.
Solution:Consult Release Notes:
For new and changed features, changes in behavior, known behavior and issues, resolved issues, and more, refer to:
Download Junos OS Software:
2. Select your product.
3. Under 'Version' on the right, select your version.
4. Click the "Software" tab.
5. Select the Install Package Release needed, and follow the prompts.
Monday, 9 February 2015
Junos: Boot from USB and Recovering from a Failed Software Upgrade
If the Junos software loads but the CLI is not working for any reason, or if the switch has no software installed, you can use this recovery installation procedure to install the Junos software.
If there is already a Junos image on the system, you can either install the new Junos package in a separate partition and both Junos images will remain on the system, or you can wipe the disk clean before the new installation proceeds.
To perform a recovery installation: Power on the switch.
Where: source: Represents the name and location of the Junos software package either on a server on the network or as a file on an external USB drive:
If there is already a Junos image on the system, you can either install the new Junos package in a separate partition and both Junos images will remain on the system, or you can wipe the disk clean before the new installation proceeds.
To perform a recovery installation: Power on the switch.
- The loader script starts.
- After the Loading /boot/defaults/loader.conf displays, you are prompted with: Hit [Enter] to boot immediately, or space bar for command prompt.
- Hit the space bar to enter the manual loader. The loader> prompt displays. (NOTE: There is a 1 second delay for hitting the space bar)
- Enter the following command:
Where: source: Represents the name and location of the Junos software package either on a server on the network or as a file on an external USB drive:
- Network address of the server and the path on the server.
- The Junos package on a USB device is commonly stored in the root drive as the only file. Example: file:///jinstall-ex-3200-10.0S1.1-domestic-signed.tgz
Monday, 2 February 2015
Signature Update Service (SUS) IP address change
Juniper is moving their Signature
Update Services (SUS) to a more robust distributed environment on 21
February 2015. As a part of this change the current IP address for the
service will no longer be valid and could affect the ability of Juniper
SSG, NS5000, ISG, and SRX products to update their signature files. All
SSG, NS5000, ISG, and SRX products should be examined to insure they
are accessing the SUS service via a URL and not the IP address.
Solution:
SSG, NS5000, ISG, and SRX products should be accessing the Signature Update Services (SUS) by connecting to the URL
https://services.netscreen.com or https://signatures.juniper.net.
If they are configured to access the SUS through one of these URLs,
they will not be affected and will continue to access the new service
without interruption on and after 21 February 2015. If the Juniper SSG, NS5000, ISG, and SRX product has been configured to use only an IP address (66.129.230.99 or 66.129.230.83), they will fail to be able update their signatures after 21 February 2015.
To prevent a failure of your firewalls not being able to update signatures after 21 February 2015, please check the configurations in each unit and change any configuration using the IP addresses to the correct URL as noted below:
- IP Address 66.129.230.99 should be replaced by URL:
https://services.netscreen.com - IP Address 66.129.230.83 should be replaced by URL:
https://signatures.juniper.net
Subscribe to:
Posts (Atom)
loading...