Using the CLI, set the following parameter
values in the console server or PC:
- Baud rate—9600
- Flow control—None
- Data—8
- Parity—None
- Stop bits—1
- DCD state—Disregard
1. To connect and configure the switch from the console
by using the CLI:
- At the Junos OS shell prompt root%, type ezsetup.
- Enter the hostname. This is optional.
- Enter the root password you want to use for the device. Reenter the root password when prompted.
- Enable services such as SSH and Telnet.Note: You will not be able to log in to the switch as the root user through Telnet. Root login is allowed only through SSH.
- The default option for SSH is yes. Select this to enable SSH.
- The default option for Telnet is no. Change this to yes to enable Telnet.
- Use the Management Options page to select the management
scenario:Note: On EX4500, EX6200, and EX8200 switches, only the out-of-band management option is available.
- Configure in-band management. In
in-band management, you configure a network interface or an uplink
module (expansion module) interface as the management interface and
connect it to the management device.
In this scenario, you have the following two options:- Use the automatically created VLAN default for management—Select this option to configure all data interfaces as members of the default VLAN. Specify the management IP address and the default gateway.
- Create a new VLAN for management—Select this option to create a management VLAN. Specify the VLAN name, VLAN ID, management IP address, and default gateway. Select the ports that must be part of this VLAN.
- Configure out-of-band management—Configure the management port. In out-of-band management, you use a dedicated management channel (MGMT port) to connect to the management device. Specify the IP address and gateway of the management interface. Use this IP address to connect to the switch.
- Configure in-band management. In
in-band management, you configure a network interface or an uplink
module (expansion module) interface as the management interface and
connect it to the management device.
- Specify the SNMP read community, location, and contact to configure SNMP parameters. These parameters are optional.
- Specify the system date and time. Select the time zone from the list. These options are optional.
- The configured parameters are displayed. Enter yes to commit the configuration. The configuration is committed as the active configuration for the switch.
- (For EX4500 switches only) Enter the operational mode command request chassis pic-mode intraconnect to set the PIC mode to intraconnect.
You can now log in with the CLI or the J-Web interface to continue
configuring the switch. If you use the J-Web interface to continue
configuring the switch, the Web session is redirected to the new management
IP address. If the connection cannot be made, the J-Web interface
displays instructions for starting a J-Web session.